Low Voltage TDR Cable Fault Locator with Rough Fault Distance Detection

Low Voltage TDR Cable Fault Locator with Rough Fault Distance Detection

Chi tiết sản phẩm:
Nguồn gốc: Tây An Sơn Tây
Hàng hiệu: XZH TEST
Chứng nhận: ISO/CE
Số mô hình: XGG501C
Thông tin chi tiết
Nguồn gốc:
Tây An Sơn Tây
Hàng hiệu:
XZH TEST
Chứng nhận:
ISO/CE
Số mô hình:
XGG501C
Làm nổi bật:

High Light

Làm nổi bật:

Rough Fault Distance Cable Fault Locator

,

Low Voltage TDR Cable Tester

,

TDR Technology Cable Fault Detector

Trading Information
Số lượng đặt hàng tối thiểu:
1 bộ
chi tiết đóng gói:
Bao bì gỗ
Thời gian giao hàng:
5-8 ngày làm việc
Điều khoản thanh toán:
T/T
Khả năng cung cấp:
3000đơn vị/năm
Mô tả sản phẩm
XHGG501C LV TDR Cable Fault Locator
The LV TDR cable fault locator provides rough fault distance measurement for low voltage cables, enabling quick identification of cable issues.
Key Features
  • Accurate rough fault distance measurement
  • Designed for low voltage cable systems
  • Time Domain Reflectometry (TDR) technology
  • Quick fault identification capability
Pulse width 0.2uS/2uS
minimum resolution 1.0M
Test blind spot ≤35m
Distance range ≥16km


Regarding waveforms


1. Standard waveform for open circuit fault

Low Voltage TDR Cable Fault Locator with Rough Fault Distance Detection 0

Analysis: At time t1, the pulse waveform generated by the flash detector is positive (but can also be negative); at time t2, the reflected pulse waveform from the intermediate joint in the cable (reflected waves from joints are generally of the same polarity, but this depends on the joint structure); at time t3, the reflected pulse waveform from an open-circuit fault is positive and of the same polarity (the polarity of the fault waveform is the same as the polarity of the pulse wave generated by the instrument); at time t4, the secondary reflected pulse waveform from the open-circuit fault. Due to pulse attenuation, the secondary reflected wave at time t4 has a smaller amplitude than the primary reflected wave at time t3. The distance S from the fault point to the measuring end is... In actual operation, by moving the cursor, the instrument will automatically display and calculate the distance to the fault point.


2. Standard waveform for low impedance fault

Low Voltage TDR Cable Fault Locator with Rough Fault Distance Detection 1

Analysis: At time t1, the pulse waveform generated by the flash detector is positive (or negative); at time t2, the reflected waveform from the intermediate joint in the cable is shown; at time t3, the reflected waveform from the low-resistance fault point is negative, representing a reflection with opposite polarity (opposite to the pulse waveform generated by the instrument); at time t4, the reflected waveform from the cable terminal is shown. The distance from the fault point to the measuring end is also considered.

Low Voltage TDR Cable Fault Locator with Rough Fault Distance Detection 2